HVAC Code Reference

Instant access to the mechanical, ventilation, refrigerant, and efficiency codes that govern HVAC work. Searchable IMC, UMC, IRC, IFGC, ACCA Manuals, ASHRAE standards, EPA Section 608, and DOE efficiency rules - built for the field.

Open Code Reference

Which Codes Govern HVAC?

Unlike electrical work, HVAC isn't ruled by a single book. It sits on a stack of codes and standards: model mechanical codes (the IMC from the ICC and the UMC from IAPMO), the mechanical chapters of the IRC for homes, the IFGC for gas-fired equipment, ACCA design manuals, ASHRAE safety and ventilation standards, and federal EPA and DOE regulations.

Which edition applies depends on your jurisdiction - states and municipalities adopt specific code years, often with local amendments. Ventora puts the key requirements from every one of those bodies in a quick, searchable reference on your phone, so you don't have to carry a shelf of code books to the job.

HVAC Code & Standard Families

Model Mechanical Codes - IMC & UMC

Prescriptive requirements for HVAC equipment, ducts, exhaust, and combustion air. IMC (ICC) is used nationwide; UMC (IAPMO) is common across the western states

Residential Mechanical - IRC

Mechanical chapters (M1201-M2500) for 1- and 2-family dwellings: equipment installation, duct sizing, appliance clearances, and ventilation

Fuel Gas - IFGC

Gas piping, appliance venting, and combustion air for gas-fired furnaces, boilers, and water heaters

Load & Duct Design - ACCA Manuals

Manual J (load calc), Manual S (equipment selection), Manual D (duct design), Manual T (air distribution), Manual N (commercial loads)

Refrigeration Safety - ASHRAE 15 & 34

Machinery rooms, refrigerant piping, and leak detection, plus A/B toxicity and 1/2L/2/3 flammability classification for refrigerants like R-454B

Ventilation & Comfort - ASHRAE 62.1 / 62.2 / 55 / 170

Minimum ventilation rates for indoor air quality, thermal comfort parameters, and healthcare facility air-change requirements

Energy - ASHRAE 90.1 & DOE

Building energy-efficiency requirements plus federal minimum SEER2, HSPF2, and AFUE ratings for equipment sold in the US

Refrigerant Regulation - EPA 608 & AIM Act

Section 608 certification (Type I / II / III / Universal), leak repair and recovery rules, and the HFC phasedown to low-GWP A2L refrigerants

Local Adoption & Amendments

Jurisdictions adopt a specific code edition and may add local amendments - always confirm the edition enforced by your AHJ

Most-Referenced Codes & Standards

Code / StandardWhat It Governs
IMCMechanical systems, ducts, exhaust, combustion air (ICC)
UMCMechanical systems - western states equivalent (IAPMO)
IRC (Ch. 12-24)Residential mechanical and duct provisions for 1-2 family dwellings
IFGCGas piping, appliance venting, and combustion air (ICC)
ACCA Manual JResidential heating and cooling load calculation
ACCA Manual SEquipment selection and acceptable sizing limits
ACCA Manual DResidential duct design and friction-rate sizing
ACCA Manual TAir distribution - registers, grilles, and diffusers
ASHRAE 15 & 34Refrigeration system safety and refrigerant classification
ASHRAE 62.1 / 62.2Ventilation for acceptable indoor air quality (commercial / residential)
ASHRAE 90.1Energy standard for commercial buildings
EPA Section 608Refrigerant handling certification, leak repair, and recovery

EPA 608 Certifications & Efficiency Rules

EPA 608 - Type I

Servicing small appliances (5 lb or less of refrigerant)

EPA 608 - Type II

High-pressure and very-high-pressure appliances (most AC / heat pumps)

EPA 608 - Type III

Low-pressure appliances (centrifugal chillers)

EPA 608 - Universal

Covers Type I, II, and III - required to handle all refrigerant systems

AIM Act

HFC phasedown - new residential/light-commercial AC must use GWP < 700 refrigerant as of Jan 1, 2025

DOE SEER2

Minimum seasonal cooling efficiency, with regional North/South standards

DOE HSPF2

Minimum seasonal heating efficiency for heat pumps

DOE AFUE

Minimum annual fuel-utilization efficiency for furnaces and boilers

Ventora HVAC Code Reference Features

🔍

Quick Search

Search by code, standard, ACCA manual, or keyword. Find the requirement you need in seconds.

📋

Organized by Body

ICC, IAPMO, ACCA, ASHRAE, EPA, and DOE references grouped for fast lookup. No more flipping between books.

📱

Built for the Field

Works offline in attics, rooftops, and crawlspaces. Designed for use on your phone.

🤖

AI Code Assistant

Ask about a code requirement and get a plain-language answer with the governing standard cited.

Field-Reference Disclaimer

Ventora summarizes HVAC codes and standards for quick field reference. It is not a substitute for the official code text. Always verify requirements against the specific code edition adopted by your jurisdiction (AHJ), the current published standard, and manufacturer installation instructions. Code editions and local amendments change over time. IMC, IRC, and IFGC are marks of the ICC; UMC of IAPMO; the Manual J/S/D/T/N series of ACCA; the 15/34/55/62.1/62.2/90.1/170 standards of ASHRAE; Section 608 and the AIM Act are administered by the US EPA; SEER2/HSPF2/AFUE by the US DOE. Ventora is not affiliated with, endorsed by, or sponsored by any of these organizations; all trademarks belong to their respective owners.

HVAC Codes in Your Pocket

Stop hauling code books to every job. Get instant IMC, UMC, IRC, IFGC, ACCA, ASHRAE, and EPA 608 lookups right on your phone with Ventora.

Download Free on App Store

7-day free trial, then $19.99/month. Cancel anytime.

Get All Features in One App

Download Ventora for instant access to AI assistant, all calculators, HVAC code reference, photo analysis, and more. Free to try.

Download on App Store