HVAC Photo Analysis

Snap a photo of a nameplate, furnace or air-handler control board, gauge manifold, or wiring diagram. Get instant AI-powered analysis with decoded fault codes and clear next steps.

Try Photo Analysis

How It Works

📸

1. Take a Photo

Snap a photo of any nameplate, control board, gauge set, or wiring diagram

🤖

2. AI Analysis

Our AI reads the image for model data, blink codes, pressures, and faults

📋

3. Get Report

Receive a plain-English breakdown with specs, diagnosis, and next steps

What Can Be Analyzed?

Equipment Nameplates

Model/serial, tonnage, refrigerant, MCA, MOCP, SEER2, RLA/FLA and charge data

Control Boards & Blink Codes

Furnace and air-handler LED fault codes, board diagnostics, sequence of operation

Gauge Manifold & Pressures

Suction and discharge readings, superheat/subcooling, saturation temps by refrigerant

Wiring Diagrams

Ladder diagrams, schematics, low-voltage control wiring, contactor and relay layouts

Refrigerant & Metering

Refrigerant type, TXV vs. fixed orifice, sight glass, filter drier, line set condition

Problem Areas

Burnt contactors, iced coils, corroded terminals, oil stains and other leak signs

AI Analysis Capabilities

✓

Nameplate Decoding

Reads model/serial, tonnage, refrigerant, MCA, MOCP, and SEER2 straight off equipment data plates

⚠️

Fault Code Diagnosis

Decodes furnace and air-handler LED blink codes and control-board faults into likely causes

📊

Pressure & Reading Interpretation

Reads gauge manifold pressures and interprets superheat and subcooling for the refrigerant in use

🔧

Troubleshooting Suggestions

Provides specific troubleshooting steps based on what it sees in the photo

📖

Code References

Cites relevant IMC/UMC, ACCA, ASHRAE, or EPA Section 608 references for any issues identified

Real-World Use Cases

Service Call Documentation

Photo existing conditions before starting work. Get AI assessment to verify your diagnosis and document what you found.

Training & Learning

Apprentices can photograph equipment they're unfamiliar with and get instant explanations of components and their function.

Estimate Preparation

Snap photos during site visits and get AI analysis to help identify scope of work and potential issues.

Second Opinion

Not sure about a blink code or an odd pressure reading? Get an AI second opinion on what you're seeing before making a call.

Try Photo Analysis Now

Take a photo of any HVAC equipment and get instant AI analysis. It's like having a senior tech looking over your shoulder.