HVAC Troubleshooting Guide

Interactive step-by-step diagnosis for HVAC problems. From no-cooling calls to furnace ignition failures and frozen coils, get systematic troubleshooting guidance with AI assistance.

Start Troubleshooting

Common HVAC Problems

🌡️ No Cooling / Warm Air

System runs but the air isn't cold, or the outdoor unit won't start

• Confirm the thermostat is set to COOL and calling (check settings/batteries)

• Check the air filter and indoor airflow first — the single most common cause

• Outdoor unit silent or humming? Suspect a failed capacitor, pitted contactor, or locked compressor

• Measure superheat & subcooling to check charge, a restricted metering device, or a dirty condenser

🔥 No Heat / Ignition Failure

Furnace runs the sequence but never lights, or the flame drops out quickly

• Watch the full sequence: inducer, igniter glow, gas valve, then flame proof

• A dirty flame sensor is the single most common no-heat call — clean it first

• Inspect the hot-surface igniter for cracks or an open circuit

• Verify gas supply and confirm the rollout and high-limit switches are closed

🧊 Frozen Evaporator Coil

Ice on the indoor coil or line set, with water around the unit when it melts

• Shut the system off and let the coil fully thaw before testing

• Replace the air filter and open every supply and return register

• Check the blower motor and wheel for dirt, slipping, or failure

• Low charge freezes coils too — verify superheat/subcooling and check for restricted ductwork

🌀 Furnace Limit / Pressure Switch Trips

Burner lights then shuts off, or the board flashes a limit or pressure fault

• High-limit trips point to low airflow: dirty filter, weak blower, or restricted ducts

• Confirm the temperature rise falls within the nameplate range

• Pressure-switch faults: check the flue, inducer motor, and condensate trap

• Blocked or disconnected ductwork raises static pressure and trips safeties

❄️ Heat Pump Iced Over / Defrost Fault

Outdoor unit encased in ice with weak heat in cold weather

• Light frost is normal; a solid ice block means the defrost cycle isn't working

• Test the defrost board, sensor, and timer for proper cycling

• A stuck reversing valve leaves the unit locked in the wrong mode

• Verify the outdoor fan runs and clear any restricted airflow around the coil

💧 Water Leak / Condensate Backup

Water around the air handler, or a system that shut itself off on a safety

• Clear the condensate drain line — algae and debris are the usual clog

• Check the drain pan and confirm the float switch is closing the circuit

• Flush the trap and verify proper slope on the drain line

• Inspect low-voltage wiring, the transformer, and connections for related faults

Systematic Troubleshooting Method

1

Gather Information

What's the complaint? When did it start? What changed recently? Interview the customer.

2

Verify the Complaint

Confirm the symptom yourself. Put your gauges, thermometers, and manometer on the system.

3

Check Airflow First

Filter, blower, coil, and ductwork. Most no-cooling and limit-trip calls trace back to airflow.

4

Divide and Conquer

Isolate the air side, refrigerant side, and electrical. Find where the readings fall out of range.

5

Test Your Theory

Make one change at a time. Verify the reading is back in range before moving on.

6

Repair and Verify

Make the repair, then confirm superheat, subcooling, delta-T, and static pressure are back in spec.

Essential Test Equipment

Digital Manifold Gauges

High- and low-side pressures with built-in PT charts, superheat, and subcooling

Clamp Meter / Multimeter

Volts, amps, ohms, capacitance, and continuity for motors and capacitors

Thermometer / Temp Clamps

Line and air temperatures for superheat, subcooling, and delta-T

Manometer

Static pressure and gas pressure measured in inches of water column

Anemometer / Flow Hood

Airflow (CFM) and face velocity at registers and grilles

Combustion Analyzer

Flue gas, CO, and efficiency readings on gas-fired equipment

AI-Assisted Troubleshooting

Ventora combines structured troubleshooting guides with AI assistance. Describe your problem or take a photo, and get intelligent suggestions for your next diagnostic step.

You

"AC runs but blows warm air. On R-410A the low side is only 45 psig and the suction line is frosting up. What should I check?"

AI

"A 45 psig low side on R-410A is about a 15°F evaporator saturation — well below normal and cold enough to frost the coil. That pattern almost always means low airflow or low charge. Work it in order: 1) Check the air filter and blower — restricted airflow is the #1 cause of a frosting coil. 2) Confirm every supply and return register is open. 3) With airflow verified, measure superheat: a high superheat with low suction points to undercharge or a restricted metering device. 4) Let the coil fully thaw before taking final charge readings, and always find and repair the leak before adding refrigerant."